Independent Representative Notice: AMP Magnetics is an independent manufacturer’s representative. We do not build, stock, or take title to product. We help you specify the requirement and route it to a manufacturer suited to build it; ratings, listings, documentation and delivery are confirmed by the manufacturer on each quotation.
Drive Power

Built for Rectifier Load, Not Just Rated for kVA

A drive isolation transformer feeds a VFD or DC drive. It is designed for the harmonic heating and short pulses of current that a rectifier front end draws, and it usually has an electrostatic shield between primary and secondary to reduce common-mode noise coupling into the plant.

You typically need one to derive a new grounded neutral, to isolate a drive from an ungrounded or corner-grounded delta supply, to match a voltage the drive cannot take directly, or to add impedance ahead of the drive. Our article Drive isolation transformers: when you actually need one goes through each case. For harmonic cancellation, see 18-pulse and 24-pulse phase-shifting designs.

Where Drive Isolation Transformers Fit

  • ■ AC VFDs: Pumps, fans, compressors and conveyors on large drives.
  • ■ DC drives: SCR DC drives on mills, extruders and winders.
  • ■ Elevators: Elevator drive supplies and modernizations.
  • ■ Ungrounded or corner-grounded supplies: Deriving a grounded wye for the drive.
  • ■ Voltage matching: Feeding 480 V drives from 600 V or other supplies.
Specification Guide

Drive Isolation Transformer Specification Guide

ParameterTypical optionsNotes
kVASized to drive input kVA, not just motor horsepowerRectifier current adds heating
Primary / secondary voltagee.g. 480 to 480Y/277, 600 to 480Y/277, 480 delta to 460 VConfirm drive input range
Electrostatic shieldSingle shield between windings is commonReduces common-mode noise coupling
ImpedanceOften around 5 to 6 percentLimits fault current and helps with line notching
Insulation and rise220 C insulation, 80/115/150 C riseLower rise means more thermal margin
EnclosureNEMA 1, 3R, 12Sealed enclosures change the thermal design

What to send for a fast, accurate quote

  • Drive make, model, horsepower and input current
  • Supply voltage and grounding (wye, delta, corner-grounded)
  • Required secondary voltage and neutral
  • Whether a shield or specific impedance is required
  • Enclosure, ambient and altitude
  • Quantity and project schedule

Specifying a Drive Isolation Transformer?

Send the drive data and the supply details. We match it to a manufacturer and return a quotation with ratings and delivery confirmed by the factory.

Open the transformer spec sheet Contact us
Common Questions

Drive isolation transformers: common questions

How do I size a drive isolation transformer?

Size it from the drive's input kVA, not only the motor horsepower. Drive manufacturers publish a recommended transformer kVA for each drive rating; the rectifier's harmonic current means a general-purpose transformer of the same kVA can run hot.

Do I need a drive isolation transformer or a line reactor?

A line reactor adds impedance and reduces harmonics and transients, but it does not isolate, change voltage, or derive a neutral. If you need isolation, a new grounded neutral, or a different voltage, you need a transformer. If you only need impedance, a reactor is smaller and cheaper.

What does the electrostatic shield do?

It is a grounded conductive layer between primary and secondary windings that diverts capacitively coupled noise to ground, reducing common-mode noise passed between the supply and the drive.

Is a K-factor transformer the same as a drive isolation transformer?

Not exactly. Both handle harmonic heating, but K-factor units are rated for a general harmonic spectrum on mixed loads, while drive isolation transformers are designed around a specific drive rectifier load and usually include a shield.

Does AMP Magnetics stock drive isolation transformers?

No. AMP Magnetics is an independent manufacturer's representative. We match your requirement to a manufacturer and coordinate the quotation; ratings and delivery are confirmed by the manufacturer.